Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bdtd.famerp.br/handle/tede/357
Registro completo de metadados
Campo DCValorIdioma
dc.creatorSilva, Lidia Maria Beloni-
dc.creator.Latteshttp://lattes.cnpq.br/5114747687288525por
dc.contributor.advisor1Beccaria, Lucia Marinilza-
dc.contributor.referee1Braile, Domingo Marcolino-
dc.contributor.referee2Paula, Adriana Aparecida Delloiagono de-
dc.date.accessioned2017-03-20T11:54:49Z-
dc.date.issued2014-08-04-
dc.identifier.citationSilva, Lidia Maria Beloni. Verificação da pressão venosa central em unidade de terapia intensiva. 2014. 47 p. Dissertação (Programa de Pós-Graduação em Enfermagem) - Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto.por
dc.identifier.doi1232por
dc.identifier.urihttp://bdtd.famerp.br/handle/tede/357-
dc.description.resumoIntrodução: A monitoração à beira do leito em unidade de terapia intensiva é considerada tecnologia de segurança obrigatória e ferramenta imprescindível na assistência ao paciente grave. Os procedimentos recomendados para monitoração hemodinâmica básica são: frequência cardíaca e respiratória, diurese, eletrocardiograma contínuo, saturação de oxigênio, pressão arterial média não invasiva e invasiva, frequência respiratória, temperatura e pressão venosa central. Objetivo: Descrever as evidências encontradas na literatura sobre a monitoração da pressão venosa central em unidade de terapia intensiva e identificar se existe diferença nos valores da medida com a cabeceira do leito do paciente em diferentes angulações. Método: A primeira parte da pesquisa foi constituída de um estudo descritivo de revisão integrativa da literatura nas bases de dados científicas PubMed, LILACS e SciELO, buscando idenficar a produção científica sobre o tema. Após análise, 15 artigos foram selecionados. Na segunda foi realizado um estudo prospectivo aberto, com abordagem quantitativa, com verificação da pressão venosa central em em quatro angulações diferentes. Os resultados foram apresentados em números absolutos e percentuais, as variáveis analisadas pelo Teste de Mann- Whitney e o teste Wilcoxon e a associação entre as medidas pela análise do coeficiente de correlação de Pearson (r) Resultados: Por meio de leitura e discussão dos artigos evidenciou-se que a monitoração pode ser realizada com o cateter posicionado em veia cava superior e inferior, com dispositivo uni ou multi-lúmen, por meio de dois sistemas: em coluna de água ou com transdutores eletrônicos de pressão. Quatro pontos devem ser seguidos no processo de monitoração: montagem do sistema, nivelamento, zeragem e resposta dinâmica. Os valores para parâmetro de normalidade da pressão devem considerar o ponto usado como eixo flebostático e a unidade de medida adotada. Os resultados devem ser analisados, associados a outros parâmetros de monitoração e ao quadro clínico do paciente. Na segunda etapa foram incluídos 156 pacientes, sendo verificada a PVC em quatro angulações diferentes, totalizando 624 medidas. Conclusão: Na primeira etapa ficou evidente que novos estudos são necessários para identificar se existem diferenças entre as várias formas de realizar o procedimento, e se os valores se alteram de acordo com a técnica utilizada. Na segunda etapa concluiu-se que a mensuração pode ser realizada com acurácia a 0º e 30º, pois apresentaram correlação positiva entre as medidas, porém a 0º e 45º a correlação é fraca demonstrando pouca associação entre as variáveis.por
dc.description.abstractIntroduction: The bedside monitoring in the intensive care unit is considered mandatory safety technology and an indispensable tool in the management of critical patients. The recommended procedures for basic hemodynamic monitoring are: cardiac and respiratory rate, diuresis, continuous electrocardiography, oxygen saturation, noninvasive and invasive mean arterial pressure, temperature, and central venous pressure. Objective: Describe the evidence regarding the procedure of central venous pressure monitoring in the intensive care unit and identify whether there are differences in the values of the pressure with the different angles of the patient’s bedside. Method: We conducted an integrative review of the literature on the scientific databases PubMed, LILACS and SciELO, seeking idenfy scientific literature on the topic. After review, 15 articles were selected. In the second stage we conducted a prospective open study with a quantitative approach, with verification of central venous pressure in four different angles. Data are expressed as absolute numbers and percentages. Variables were analyzed with the Mann-Whitney test and the Wilcoxon test. Associations between measures were test by Pearson’s correlation coefficient (r) Results: Through the reading and discussion of the articles we identified that the monitoring can be performed with the catheter positioned in the superior vena cava and inferior device with single or multilumen, through two systems in the water column or the electronic pressure transducers. Four points should be followed in the monitoring process: mounting system, leveling, zeroing and dynamic response. The values for parameter of normal pressure must consider the point used as the phlebostatic axis and the unit of measurement used. The results should be analyzed together with other monitoring parameters and the patient’s condition. In the second stage 156 patients, checked the central venous pressure in four different angles, totaling 624 measures were included. Conclusion: Further studies are needed to identify whether there are differences between the various forms of performing the procedure, and if the values change according to the technique used. We found a positive linear correlation between the measures 0º and 30º, but in 0 ° and 45 ° the correlation is weak showing little association between the variables.eng
dc.description.provenanceSubmitted by Fabíola Silva (fabiola.silva@famerp.br) on 2017-03-20T11:54:49Z No. of bitstreams: 1 lidiamariabelonisilva_dissert.pdf: 985957 bytes, checksum: d191961fe0b9e78f9e0c8325a666d58b (MD5)eng
dc.description.provenanceMade available in DSpace on 2017-03-20T11:54:49Z (GMT). No. of bitstreams: 1 lidiamariabelonisilva_dissert.pdf: 985957 bytes, checksum: d191961fe0b9e78f9e0c8325a666d58b (MD5) Previous issue date: 2014-08-04eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherFaculdade de Medicina de São José do Rio Pretopor
dc.publisher.departmentFaculdade 1::Departamento 1::306626487509624506::500por
dc.publisher.countryBrasilpor
dc.publisher.initialsFAMERPpor
dc.publisher.programPrograma de Pós-Graduação em Enfermagem::5708931012041588413::500por
dc.rightsAcesso Abertopor
dc.subjectCentral Venous Pressureeng
dc.subjectNursing Careeng
dc.subjectCritical Careeng
dc.subjectPressão Venosa Centralpor
dc.subjectCuidados de Enfermagempor
dc.subjectCuidados Críticospor
dc.subject.cnpqENFERMAGEM::ENFERMAGEM DE SAUDE PUBLICA::5647390027954931658::600por
dc.titleVerificação da pressão venosa central em unidade de terapia intensivapor
dc.typeDissertaçãopor
Aparece nas coleções:Programa de Pós-Graduação em Enfermagem

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
lidiamariabelonisilva_dissert.pdflidiamariabelonisilva_dissert962,85 kBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.