Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bdtd.famerp.br/handle/tede/366
Registro completo de metadados
Campo DCValorIdioma
dc.creatorGonçalves, Fausto da Silva-
dc.creator.Latteshttp://lattes.cnpq.br/7465045815937259por
dc.contributor.advisor1Oliani, Antonio Hélio-
dc.contributor.referee1Ferlin, Rejane Maria-
dc.contributor.referee2Cabrera, Eliana Márcia Sotello-
dc.date.accessioned2017-05-26T12:24:58Z-
dc.date.issued2013-03-14-
dc.identifier.citationGonçalves, Fausto da Silva. Avaliação dos parâmetros de imagens de massas anexiais pélvicas em tele-ecografia. 2013. 52 p. Dissertação (Programa de Pós-Graduação em Ciências da Saúde) - Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto.por
dc.identifier.doi1207por
dc.identifier.urihttp://bdtd.famerp.br/handle/tede/366-
dc.description.resumoIntrodução: De acordo com a Organização Mundial de Saúde, o diagnóstico por imagem é um procedimento necessário para o tratamento acurado de pelo menos 25% dos pacientes em todo o mundo. Embora a tecnologia de imagem tenha evoluído de forma vertiginosa, mais de 90% de todas as imagens necessárias podem ser realizadas com máquinas simples de Ultrassonografia e Raios-X. Há dados indicando a Ultrassonografia Transvaginal como um dos métodos mais efetivos para detecção de tumores ovarianos, por ser seguro, rápido, fácil de realizar e bem aceito pelas pacientes. É o exame mais utilizado para esse propósito devido a sua excelente relação custo/benefício, ser um método inócuo e amplamente utilizado no diagnóstico de massas anexiais. Inúmeros estudos têm sido realizados para diferenciar as massas anexiais e assim reduzir o número de pacientes submetidas a tratamentos inadequados. Objetivos: Avaliação dos parâmetros ultrassonográficos relacionados com as características morfológicas de massas anexiais pélvicas através da obtenção de imagens bidimensionais realizadas por observador presencial e encaminhadas eletronicamente (via Tele-Ecografia) no modo estático e dinâmico a observadores não presenciais (à distância) para análises comparativas inter e intra- observadores e validação de uma segunda opinião. Casuística e métodos: No período de março a agosto de 2010 foram selecionadas 50 pacientes por apresentarem visualização de massa anexial ao exame ecográfico. Os exames ultrassonográficos pélvicos foram realizados por via abdominal e por via endovaginal na Unidade de Imagenologia do Departamento de Ginecologia e Obstetrícia do Hospital de Base de São José do Rio Preto. As massas anexiais foram avaliadas de acordo com suas características morfológicas. Resultados: Houve uma boa concordância inter-examinadores independente da modalidade (dinâmica e estática) utilizada. Conclusões: Os parâmetros ultrassonográficos das características morfológicas de massas anexiais pélvicas encaminhadas por Tele-Ecografia são passíveis de serem validadas para a emissão de uma segunda opinião. Não houve diferenças significativas quanto à metodologia empregada na emissão das imagens tele-ecograficas (estática ou dinâmica) na caracterização da composição das massas anexiais pélvicas.por
dc.description.abstractIntroduction: According to the World Health Organization, is a diagnostic imaging procedure necessary for the accurate treatment of at least 25% of patients worldwide. While the imaging technology has evolved so dizzying, over 90% of all images required can be performed with simple machines to ultrasound and X- rays. There are data indicating Transvaginal Ultrasonography as one of the most effective methods for detecting ovarian tumors, to be safe, fast, easy to perform and well accepted by patients. It is the most frequently used test for this purpose due to its excellent cost / benefit ratio, being an innocuous and widely used method in the diagnosis of adnexal masses. Numerous studies have been conducted to differentiate adnexal masses and thereby reduce the number of patients subjected to inappropriate treatment. Objectives: Evaluation of sonographic parameters related with the morphological characteristics of pelvic adnexal masses by obtaining two-dimensional images taken by observer presence and sent electronically (via Tele-Ultrasound) in static mode and dynamic observers do not face (distance) for comparative analyzes inter-and intra-observer and validation of a second opinion. Methods: From March to August 2010 50 patients were selected for presenting viewing adnexal mass on ultrasound. The pelvic sonographic examinations were performed by cesarean section and by vaginal Imaging Unit in the Department of Obstetrics and Gynecology, Hospital de Base in São José do Rio Preto. The adnexal masses were evaluated according to their morphological characteristics. Results: There was good inter-rater agreement independent of the modality (dynamic and static) used. Conclusions: The sonographic parameters of the morphological characteristics of pelvic adnexal masses directed by Tele-Ultrasound is capable of being validated for issuing a second opinion. There were no significant differences in the methodology employed in the issue of tele-ultrasound images (static or dynamic) to characterize the composition of pelvic adnexal masses.por
dc.description.provenanceSubmitted by Fabíola Silva (fabiola.silva@famerp.br) on 2017-05-26T12:24:58Z No. of bitstreams: 1 faustodasilvagonçalves_dissert.pdf: 1310792 bytes, checksum: 52a5579dab6c9a6b5bf94f7d828a2eef (MD5)eng
dc.description.provenanceMade available in DSpace on 2017-05-26T12:24:58Z (GMT). No. of bitstreams: 1 faustodasilvagonçalves_dissert.pdf: 1310792 bytes, checksum: 52a5579dab6c9a6b5bf94f7d828a2eef (MD5) Previous issue date: 2013-03-14eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherFaculdade de Medicina de São José do Rio Pretopor
dc.publisher.departmentFaculdade 1::Departamento 1::306626487509624506::500por
dc.publisher.countryBrasilpor
dc.publisher.initialsFAMERPpor
dc.publisher.programPrograma de Pós-Graduação em Ciências da Saúde::6954410853678806574::600por
dc.rightsAcesso Abertopor
dc.subjectDirect Parameterseng
dc.subjectUltrasonicseng
dc.subjectPelviseng
dc.subjectParâmetros Diretospor
dc.subjectUltrassompor
dc.subjectPelvepor
dc.subject.cnpqCIENCIAS DA SAUDE::8765449414823306929::600por
dc.titleAvaliação dos parâmetros de imagens de massas anexiais pélvicas em tele-ecografiapor
dc.typeDissertaçãopor
Aparece nas coleções:Programa de Pós-Graduação em Ciências da Saúde

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
faustodasilvagonçalves_dissert.pdffaustodasilvagonçalves_dissert1,28 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.