Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bdtd.famerp.br/handle/tede/114
Registro completo de metadados
Campo DCValorIdioma
dc.creatorFinoti, Renata Geronpt_BR
dc.contributor.advisor1Braile, Domingo Marcolinopt_BR
dc.contributor.advisor1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4767966J3&dataRevisao=nullpor
dc.contributor.referee1Crotti, Ulisses Alexandrept_BR
dc.contributor.referee2Antunes, Nilsonpt_BR
dc.contributor.referee2Latteshttp://lattes.cnpq.br/4219019335309966por
dc.date.accessioned2016-01-26T12:51:32Z-
dc.date.available2012-06-26pt_BR
dc.date.issued2011-11-29pt_BR
dc.identifier.citationFINOTI, Renata Geron. Avaliação de oxigenador de membrana infantil em ovinos. 2011. 55 f. Dissertação (Mestrado em Medicina Interna; Medicina e Ciências Correlatas) - Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto, 2011.por
dc.identifier.urihttp://bdtd.famerp.br/handle/tede/114-
dc.description.resumoAnalisar a segurança e a eficácia de um novo oxigenador de membrana denominado OXM -1500. Métodos: No período de maio de 2005 a setembro de 2006, foram estudados seis ovinos da raça Santa Inês, sendo cinco machos e uma fêmea, com peso corpóreo médio de 14,1 (±5) kg, superfície corpórea de 0,6 (±0,2) m2 e idade média de 3,8 (±1,5) meses. Todos foram submetidos à circulação extracorpórea (CEC) com avaliação nos tempos 10, 30, 60, 120, 180 e 240 minutos, obtendo-se os valores de taxa de transferência de oxigênio (TTO2) e de taxa de transferência de gás carbônico (TTCO2), hemoglobina sérica (HBS) e livre (HBL), plaquetometria, leucometria e taxa de transferência de calor. Resultados: Houve adequadas TTO2 e TTCO2. A lesão da maioria dos elementos figurados do sangue foi insignificante, sem alterações dos níveis de HBS, HBL, plaquetas e o número de leucócitos diminuíram com o tempo. A troca de calor foi efetiva (p ≤ 0,05). Conclusão: O oxigenador de membrana infantil OXM-1500, testado em ovinos, mostrou-se com capacidade adequada de oxigenação, remoção de gás carbônico e pequena alteração da hemoglobina e plaquetas, com diminuição do número de leucócitos de forma esperada. O trocador de calor acoplado ao oxigenador foi eficaz nas variações de temperatura.por
dc.description.abstractTo analyze the security and efficacy of a new membrane oxygenator, the so-called OXM 1500. Methods: From May 2005 to September 2006, six sheep of Santa Inês breed (5 male and 1 female, respectively) were studied. The average body weight was 14.1 (±5) kg, body surface 0.6 (±0.2) m2 and a mean age 3.8 (±1.5) months. All of them were submitted to extracorporeal circulation (CEC) with evaluation at 10, 30, 60, 120, 180 and 240 minutes. The following values were obtained: values of oxygen transference (TTO2) and carbon dioxide transference (TTCO2), haemoglobin (HBS) and free haemoglobin (HBL), the score of platelets and of leucocytes, and heat transference rate. Results: TTO2 and TTCO2 were adequate. Lesion of the majority formed blood elements was insignificant; there no modifications in HBS, HBL levels; platelets and leucocytes decreased over time. Heat exchange was effective (p ≤ 0.05). Conclusions: The membrane OXM 1500 infant oxygenator, tested in sheep, showed adequate oxygenation capacity, CO2 removal capacity, and small alteration of haemoglobin and platelets without significant decrease of leucocytes, as expected. Heat exchanger connected to the oxygenator was efficient in temperature changes.eng
dc.description.provenanceMade available in DSpace on 2016-01-26T12:51:32Z (GMT). No. of bitstreams: 1 renatageronfinoti_dissert.pdf: 2240331 bytes, checksum: e80f129b0db02c473d3a9c4f5162e004 (MD5) Previous issue date: 2011-11-29eng
dc.formatapplication/pdfpor
dc.languageporpor
dc.publisherFaculdade de Medicina de São José do Rio Pretopor
dc.publisher.departmentMedicina Interna; Medicina e Ciências Correlatas::123123123123::600por
dc.publisher.countryBRpor
dc.publisher.initialsFAMERPpor
dc.publisher.programPrograma de Pós-Graduação em Ciências da Saúde::123123123123::600por
dc.rightsAcesso Abertopor
dc.subjectMembrane Oxygenatoreng
dc.subjectOvineseng
dc.subjectExtracorporeal Circulationeng
dc.subjectCardiologyeng
dc.subjectOxygenators, Membraneeng
dc.subjectSheepeng
dc.subjectOxigenadores de Membranapor
dc.subjectOvinospor
dc.subjectCirculação Extracorpóreapor
dc.subjectCirculación Extracorporeaspa
dc.subject.cnpqCNPQ::CIENCIAS DA SAUDE::MEDICINA::CLINICA MEDICA::CARDIOLOGIA::123123123123::600por
dc.titleAvaliação de oxigenador de membrana infantil em ovinospor
dc.typeDissertaçãopor
Aparece nas coleções:Programa de Pós-Graduação em Ciências da Saúde

Arquivos associados a este item:
Arquivo TamanhoFormato 
renatageronfinoti_dissert.pdf2,19 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.